The VERIFY SixCess Steam Indicator Strips are Type 6 Emulating Indicators as defined by American National Standards Institute/Association of the Advancement of Medical Instrumentation/International Standards Organization (ANSI/AAMI/ISO) 11140-1. Each emulating indicator has been specifically designed for the exposure time required for a specific cycle, for example, 270°F (132°C) four minute prevacuum cycle, 270°F (132°C) fifteen minute gravity cycle, etc.
How VERIFY SixCess Steam Integrator Strips Work
The distinctive total color change helps to avoid misinterpretation of results, compared to other indicators that exhibit a gradual change. The VERIFY SixCess Indicators provide cycle-specific monitoring allowing high-quality sterility assurance monitoring in every sterilized pack. The results are accurate to 1°C and 6% of the stated exposure time.
Why VERIFY SixCess Steam Integrator Strips
These Type 6 steam indicator strips offer the following benefits to help promote precision, ease of use, and patient safety:
Browse a complete Item Number list and easily reorder VERIFY™ SixCess® Steam Indicator Strips products on Shop STERIS.
Product Number | Description | Programmed Sterilization Cycle | |
---|---|---|---|
PCC031 | VERIFY SixCess 270F 15 Minute Indicator (1 bx/100 indicators) | 270°F / 132°C, 15 minute Gravity Cycle | |
PCC034 | VERIFY SixCess 275F 3 Minute Indicator Long (1 bx/100 indicators) | 275°F / 132°, 3 minute Prevacuum Cycle | |
PCC038 | VERIFY SixCess 275F 3 Minute Indicator Short (1 bx/200 indicators) | 275°F / 132°, 3 minute Prevacuum Cycle | |
PCC005 | VERIFY SixCess 250F 30 Minute Indicator Short (1 bx/200 indicators) | 250°F / 121°C, 30 minute Gravity Cycle | |
PCC006 | VERIFY SixCess 270F 4 Minute Indicator Short (1 bx/200 indicators) | 270°F / 132°C, 4 minute Dynamic Air Removal* Cycle | |
PCC007 | VERIFY SixCesss 250F 30 Minute Indicator Long (1 bx/100 indicators) | 250°F / 121°C, 30 minute Gravity Cycle | |
PCC008 | VERIFY SixCess 270F 4 Minute Indicator Long (1 bx/100 indicators) | 270°F / 132°C, 4 minute Dynamic Air Removal* Cycle |
*Dynamic Air Removal Cycle includes Vacuum assisted and Steam-Flush Pressure-Pulse Systems.
SDS
|
|
---|---|
Document # | Document Title |
VERIFY SIXCESS STEAM INDICATOR STRIPS | |
VERIFY SIXCESS STEAM INDICATOR STRIPS - CANADIAN | |
VERIFY SIXCESS STEAM INDICATOR STRIPS - UNITED KINGDOM |
WALL CHARTS
|
|
---|---|
Document # | Document Title |
VERIFY SIXCESS INDICATOR STRIPS SELECTION, USE AND INTERPRETATION GUIDE | |
VERIFY SIXCESS INDICATOR STRIPS SELECTION, USE AND INTERPRETATION GUIDE | |
VERIFY SIXCESS INDICATOR STRIPS SELECTION, USE AND INTERPRETATION GUIDE |
SAMPLE PROCEDURES
|
|
---|---|
Document # | Document Title |
SAMPLE PROCEDURES VERIFY SIXCESS CHEMICAL INDICATOR STRIPS FOR INTERNAL PACK MONITORING |
BROCHURE
|
|
---|---|
Document # | Document Title |
VERIFY SIXCESS CHEMICAL INDICATORS AND CHALLENGE PACKS |