Select Your Region
Monitor loads and remain compliant with device Instructions For Use (IFUs) requiring 10-minute cycles. The Celerity Xtend 10 Assembly is used with the VERIFY All-In-One STEAM Reusable Test Pack. It is validated for routine monitoring of 270°F/132°C dynamic air removal steam sterilization cycles with a 10-minute exposure time.
How the Celerity Xtend 10 Assembly Works
The Celerity Xtend 10 Assembly is a preassembled plastic vial with a rubber cap containing both a Celerity 20 STEAM BI and a Celerity 10 STEAM Chemical Indicator (CI). The assembly is placed in the VERIFY All-In-One STEAM Reusable Test Pack to form the BI challenge (test) pack. The complete test pack is then placed at the most challenging location of the sterilizer, typically on the bottom rack near the drain. After the cycle, the clear plastic housing allows for immediate interpretation of the chemical indicator. The BI is then incubated and read within 20 minutes in a universal Celerity™ Incubator or Celerity™ STEAM Incubator.
Why the Celerity Xtend 10 Assembly
Product Specifications
Sterilization Method |
Steam Sterilization |
|
Validated Cycles |
10-minute 270°F/132°C dynamic air removal cycles |
|
Product Type |
Biological Indicator Test Pack |
|
Size |
0.83 x 3.9 inches (21 x 100 mm) |
|
SKU |
LCB054 |
|
CI Interpretation |
UNPROCESSED |
|
PASS: Color change from yellow to blue/purple |
||
FAIL: Color does not change from |
||
BI Process Indicator Interpretation |
UNPROCESSED |
|
PROCESSED |
Browse a complete Item Number list and easily reorder Celerity™ Xtend 10 Assembly products on Shop STERIS.
Product Number | Description | |
---|---|---|
LCB054 | CELERITY XTEND 10 ASSEMBLY (30 TEST PACKS 30 CONTROL) | |
LCB060 | CELERITY INCUBATOR (UNIVERSAL) |
TECH DATA SHEET
|
|
---|---|
Document # | Document Title |
CELERITY XTEND 10 ASSEMBLY (LCB054) | |
CELERITY XTEND 10 ASSEMBLY (LCB054)-FR |
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
TECHNICAL DATA MONOGRAPH - CELERITY 20 STEAM BI, BI FOR IUSS, PCD AND XTEND 10 ASSEMBLY | |
MONOGRAPHIE DES DONNÉES TECHNIQUES - CELERITY 20 STEAM BI, BI FOR IUSS, PCD AND XTEND 10 ASSEMBLY |
SAMPLE PROCEDURES
|
|
---|---|
Document # | Document Title |
ROUTINE BIOLOGICAL AND LOAD MONITORING USING THE CELERITY™ XTEND10 ASSEMBLY WITH THE VERIFY ALL-IN-ONE STEAM REUSABLE TEST PACK |
BROCHURE
|
|
---|---|
Document # | Document Title |
CELERITY FAMILY BROCHURE | |
CELERITY FAMILY BROCHURE | |
CELERITY FAMILY BROCHURE |
SDS
|
|
---|---|
Document # | Document Title |
CELERITY 20 STEAM BIOLOGICAL INDICATORS AND CHALLENGE PACKS |