STERIS Certified Pre-Owned Medivators DSD Edge Automated Endoscope Reprocessor
STERIS Corporation - Helping to provide a healthier today and a safer tomorrow.

STERIS Certified Pre-Owned Medivators DSD Edge™ Automated Endoscope Reprocessor

  • Brand: STERIS
  • Model: DSD Edge™ Dual Basin AER
  • Key Feature: Shorter reprocessing cycle time delivers quick turnaround of flexible endoscopes
  • Clinical Application: Provides high-level disinfection for infection prevention in simultaneous or independent cycles

Product Overview

The STERIS Certified Pre-Owned DSD Edge™ Automated Endoscope Preprocessor (AER) is a dual basin unit that provides high-level disinfection as fast as 22 minutes and incorporates two fully independent and asynchronous reprocessing basins using single-use peracetic acid chemistry RAPICIDE™ PA disinfectant. Additionally, the DSD Edge AER offers performance-enhancing features like an endoscope leak test, alcohol air purge, cycle information printing, a pre-filtration system, built-in air compressors, and more.

This refurbished DSD Edge AER is designed to use RAPICIDE™ PA High-Level Disinfectant, a single-use and environmentally friendly peracetic acid-based disinfectant. After the disinfecting cycle, an automated alcohol flush supports the air drying of endoscope channels. The large, dual basins accommodate most endoscope sizes and allow biomedical engineers to process two scopes simultaneously or on independent cycles for a continuous workflow.

Each STERIS Certified Pre-Owned (CPO) DSD Edge AER is thoroughly inspected and refurbished as part of an extensive process conducted by certified technicians. The unit is ensured to meet STERIS specifications to be like-new aesthetically and operationally.

Disclaimer:

  • The STERIS Certified Pre-Owned Equipment program is offered solely by STERIS and is not affiliated with, endorsed by, or supported by other Original Equipment Manufacturers (OEMs). STERIS Certified Pre-Owned Equipment is refurbished by STERIS.
  • Product specifications and information could differ depending on the manufacturer, date of manufacture, product series, or model or as determined by the Original Equipment Manufacturer (OEM), and are subject to change. As a reseller of pre-owned equipment, STERIS refurbishes to any known or available performance characteristics for the specific series or model of the product. All Certified Pre-Owned Equipment undergoes a multi-point functionality inspection and is certified to meet STERIS Certified Pre-Owned Equipment Refurbishing Program standards.
  • STERIS Certified Pre-Owned Equipment may or may not include OEM resource materials (e.g., instruction manuals, guides, and other documentation) or OEM parts.
  • For warranty information, please see: STERIS Certified Pre-Owned Equipment Warranty
  • Operations located in North America; STERIS Certified Pre-Owned Equipment is intended for sale within the Americas.
Go to Top of Page
 

Specifications

FEATURE DESCRIPTION
Dimensions
  • 46 H x 36W x 21 D" (117 H x 91 W x 53 D cm)
  • Height with lid open: 64"
Weight
  • 400 lbs. (182 kg)
Electrical Requirements
  • 120VAC, 60Hz, 1440 watts
Electrical Safety Certifications
  • ETL Intertek Listed #75811
  • UL Standard 61010
  • CSA/CSA Standard C22.2, No. 601.1
Water Supply Requirements
  • Minimum Flow Rate: 3.2 GPM (12LPM) at 35-40 PSI (2.4 - 2.8 bar)
  • Water Temperature: 95°F ± 4°F (35°C ± 2°C)
Reservoir Capacities
  • Alcohol and Detergent: 27oz each (800 ml)
Disinfectant Temperature Range
  • RAPICIDE™ PA Disinfectant 30°C - 40°C (86°F - 104°F)
Go to Top of Page
 

STERIS Certification Process

Medivators AERs from STERIS CPO are refurbished products that undergo precise STERIS certification process. STERIS CPO technicians thoroughly inspect and refurbish each unit to meet STERIS specifications to be like-new aesthetically and operationally.

Diagnostics/Inspections

Through this step STERIS CPO technicians ensure quality and adherence to OEM standards, committed to preserving equipment reliability. Our program conducts a series of thorough inspections.

  • Inspect the unit for leaks
  • Verify Leak Tester option functionality
  • Verify the operation of the GFI outlet
  • Verify adjustment of drain times
  • Extensive cycle validation to ensure functionality
  • Check the unit for proper labeling and clean area. Wipe down the unit.
  • Open all valves and allow water to escape all valves and no pooling water

Conditional Replacement/Refurbishment

STERIS CPO refurbishes each Medivators AER to meet the OEM performance and quality standards. Our AER Certification Process restores equipment as an all-encompassing service.

  • Rebuild all valves
  • Replace valve seals
  • Replace filters
  • Replace disinfection pump
  • Replace the scanner and monitor
  • Replace damaged, discolored or stained plastic exterior components
  • Rebuild the SSG unit
  • Replace tubing and hoses
  • Replace dosing pumps
  • Replace o-rings on pumps, dosing reservoirs, and drain manifold
  • Replace springs and rubber balls on dosing reservoirs
  • Replace the squeeze tube for the alcohol and detergent delivery pump
Go to Top of Page
 

Literature

There are no literature documents found for this document.
Go to Top of Page
 

Related Products