VERIFY Biological Steam Test Indicator Pack | STERIS
STERIS Corporation - Helping to provide a healthier today and a safer tomorrow.

VERIFY Biological Steam Test Pack

  • Read Time: Provides results in 24 hours
  • Cycles: Dynamic Air Removal Cycles at 270°F/132°C and Gravity Cycles at 250°F/121°C
  • Feature: Equivalent performance to ANSI/AAMI 16-towel test pack

Shop Now

PRODUCT OVERVIEW

VERIFY Biological Monitoring products provide critical confirmation for sterility assurance programs and are used to monitor dynamic air removal (prevacuum and steam-flush pressure-pulse) steam sterilization cycles performed at 270°F/132°C and gravity cycles performed at 250°F/121°C.

How VERIFY Biological Steam Test Pack Works

The pack tests a steam sterilizer's ability to kill Geobacillus stearothermophilus spores, with each pack containing a chemical indicator and a VERIFY® Self-Contained Biological Indicator.

Check out the new:

Celerity™ 20 STEAM Process Challenge Device

Celerity 20 STEAM Process Challenge Device for fast 20 minute results.

The test pack is placed toward the bottom front of the loaded autoclave chamber near the drain. After the cycle has completed, technicians should immediately remove the challenge pack from the sterilizer and allow cooling before interpreting the chemical indicators and incubating the biological indicator for 24-hours before final results are read. See the instructions sheet enclosed in each box for detailed use directions.

Why VERIFY Biological Steam Test Packs

VERIFY Biological Steam Test Packs are easy-to-use and offer:

  • Compact design to easily fit into fully loaded chambers
  • 24-hour incubation time
  • Vivid biological indicator color change and clear results from the chemical indicator
Go to Top of Page
 

SHOP NOW

Browse a complete Item Number list and easily reorder VERIFY® Biological Steam Test Pack on Shop STERIS.

Product Number Description Quantity  
S3065 VERIFY Biological Steam Test Pack Box (20 packs and 5 controls)
S3069 VERIFY Biological Steam Test Pack Box (20 packs and 20 controls)

An incubator and activator set are required for proper use of the VERIFY® Biological Steam Test Pack.

Product Number Description Quantity  
S3075 VERIFY™ Vial Activator Set Each
S3080 VERIFY™ 28 Well Dual Incubator (55-60°C and 35-39°C) Each
S3082 VERIFY™ 28 Well Incubator for Steam (55-60°C) Each
S3271 VERIFY™ 6 Well Steam Incubator (55-60°C) Each
Go to Top of Page
 

Literature

TECH DATA SHEET
Document # Document Title
VERIFY DUAL TEMPERATURE 28-WELL INCUBATOR (220 VAC) FOR VERIFY SELF-CONTAINED BIOLOGICAL INDICATORS (S3081)
VERIFY BIOLOGICAL STEAM TEST PACK S3065/S3069
BROCHURE
Document # Document Title
VERIFY BIOLOGICAL MONITORING PRODUCTS BROCHURE
SAMPLE PROCEDURES
Document # Document Title
SAMPLE PROCEDURE: STEAM STERILIZATION LOAD MONITORING WITH THE VERIFY SIXCESS CHALLENGE PACKS AND THE VERIFY BIOLOGICAL STEAM BIOLOGICAL TEST PACK
SDS
Document # Document Title
VERIFY SCBI AND TEST PACKS
MSDS
Document # Document Title
VERIFY SCBI AND TEST PACKS - ITALIAN
VERIFY SCBI AND TEST PACKS - PORTUGUESE
VERIFY SCBI AND TEST PACKS - UNITED KINGDOM