V-PRO S2 Low Temperature Sterilization System | STERIS
STERIS Corporation - Helping to provide a healthier today and a safer tomorrow.

V-PRO™ s2 Low Temperature Sterilization System

  • Capacity - Process up to 25lbs in 28 minutes, or 4 lbs in as quick as 19 minutes
  • Features - Small footprint at less than 2 feet wide easily fits in space constrained departments
  • Compatibility - Compatible with the widest range of medical devices and materials

Browse Replacement Parts

Product Overview

The V-PRO s2 Low Temperature Sterilizer delivers the right cycles to meet your Sterile Processing Departments' (SPD) demands while fitting in the tightest spaces of your facility at just 22 ½" wide. This compact, low temperature sterilizer also offers a 19-minute cycle for quick turnaround of devices. Delivering maximum productivity.

How the V-PRO s2 Low Temperature Sterilization System Works

The V-PRO s2 Low Temperature Sterilization System is a vaporized hydrogen peroxide (VH2O2) sterilizer that uses VAPROX™ HC Sterilant and provides terminal sterilization of properly prepared (cleaned, rinsed, and dried) medical devices. This compact sterilizer offers pre-programmed cycles that operate at low temperatures, processing medical devices without leaving toxic residues. Pre-programmed cycles include:

Cycle LumenLumen Non-LumenNon Lumen FlexibleFlexible Fast Non-LumenFast

Refer the operator manual for lumen size limitations.

*da Vinci is a registered trademark of Intuitive Surgical, Inc.

Cycle Time 60 minutes 60 Minutes 28 minutes28 Minutes 38 minutes 38 Minutes 19 minutes 19 Minutes
Load Weight ≤ 11lb/5 kg ≤25 lb/11.3 kg 1 Scope | ≤11 lb/ 5kg:
1 Scope and Non Lumened
and Lumened Devices
≤4 lb/1.8 kg,
Peel Pouch Only
Device Examples
  • Orthopedic Drill
  • Camera
  • da Vinci S® and
    da Vinci Si®
    Endoscopes*
  • Batteries
  • Telescopes
  • Lumened Rigid
    Endoscopes
  • Light Cord
  • Batteries
  • Camera
  • da Vinci S® and
    da Vinci Si®
    Endoscopes*
  • Telescopes
  • Non Lumened
    Rigid and Flexible
    Endoscopes
  • Lumened Flexible
    Endoscopes
  • Light Cord
  • Camera
  • da Vinci S® and
    da Vinci Si®
    Endoscopes*
  • Batteries
  • Telescopes
  • Orthopedic Drill
  • Camera
  • Batteries
  • Light Cord
  • Telescopes
  • Lumened Rigid
    Endoscopes
  • Non Lumened
    Flexible
    Endoscopes

Please refer to the Operator Manual for detailed lumen dimension information and how to identify devices for loads.

Why Choose the V-PRO s2 Low Temperature Sterilization System?

  • Size: At just 22 ½" wide, the compact V-PRO s2 Sterilizer can easily fit into space-constrained locations.
  • Throughput: Faster VH2O2 sterilization cycles and more flexibility than any other small low temperature sterilizer on the market.
  • Compatibility: V-PRO Sterilizers work with the widest range possible of medical devices and materials – 87% more device materials than the leading competitor.
  • Safety: Innovative foot sensor makes hands-free loading quick, safe, and easy. V-PRO Sterilizers are designed with numerous safety features, and STERIS considers established OSHA and AAMI Standards in developing our IFUs and making safety recommendations. Click Here to Learn about V-PRO Safety Features.
  • Instructional Videos: The V-PRO s2 Sterilizer makes tasks more straightforward and easier to train staff and stay compliant with instructional videos available on the sterilizer screen.
Environmental Social Governance

Supporting Your Sustainability Goals

 

  • Conserve Utilities – Sterilize devices with no water consumption or wastewater produced using significantly less electricity than steam sterilization - only 2.3 kWh/cycle. Sterilizer does not generate notable heat that can impact the HVAC load.

Learn more about Sustainability at STERIS

Go to Top of Page
 

Specifications

  • Overall Sterilizer Dimensions are 22 ½" Wide x 32 ⅞" Deep x 61 ½" Tall
  • Chamber Size is 13" x 28" x 10" with 2.1 cubic feet of volume
  • Utility Requirements - no plumbing, special ventilation, or air supply. Only a standard 20amp dedicated wall outlet is needed
Go to Top of Page
 

Device Compatibility

Confirm that your medical devices and accessories are compatible for processing with our Low Temperature Systems.

SEARCH FOR MY DEVICES

Commonly Searched Devices Validated for Use in V-PRO Sterilizers

Olympus®

Device Type Model
Bronchoscopes BF, such as BF1T60
Cystoscopes CYF, such as CYF V2
Pleuroscope LTF, such as LTF VH1

Karl Storz®

Device Type Model
Ureteroscope 11278AU1
Rhino Pharyngoscope 11101RP2
C-Mac Intubation Fiberscope 11302BD2
Fiberscope  

Stryker®

Device Type Model

HD Cameras
System 7 set

1488-010-000
Sternum saw
7207-000-000

Medline®

Device Type Model
Sterilization Wraps Various

Cardinal Health™

Device Type Model
Sterilization Wraps Various

Halyard Health®

Device Type Model
Sterilization Wraps Various

Visit the V-PRO Device Matrix to find out if your device can be reprocessed in a V-PRO Low Temperature Sterilization System. The Device Matrix contains information on devices from hundreds of manufacturers including:

  • Aesculap
  • Arthrex
  • BK Ultrasound
  • Brainlab
  • Braun
  • Cardinal Health
  • Fisher & Paykel
  • GE Healthcare
  • Halyard Health
  • Hitachi Aloka
  • Intuitive Surgical
  • Karl Storz
  • Medline
  • Medovations
  • Mizuho
  • Olympus
  • Philips
  • Richard Wolf
  • St. Jude Medical
  • Stryker
  • Teleflex
  • Truphatek
  • Volk
  • WelchAllyn
Go to Top of Page
 

Connectivity and Electronic Record Management with ConnectAssure™ Technology

Seamlessly connect and get immediate results from your V-PRO s2 Low Temperature Sterilizer and Celerity Incubator with ConnectAssure Technology. ConnectAssure Technology Data Export software helps promote compliance throughout the facility by interfacing compatible STERIS products with SPM Surgical Asset Tracking Software and many of the other leading instrument tracking systems.

Go to Top of Page
 

FAQs

What can the V-PRO s2 Low Temperature Sterilizer sterilize?

The V-PRO s2 Low Temperature Sterilizer can sterilize more than just instruments that are heat sensitive. Devices like batteries, rigid endoscopes, general stainless steel instruments, bronchoscopes, and others will benefit from short cycle times with a gentle, low temperature process.

How fast can the V-PRO s2 Low Temperature Sterilizer sterilize?

The V-PRO s2 Low Temperature Sterilizer has four cycles that range from fast to extremely fast, with all cycles starting with a moisture checking condition phase included in the total time:

  • The Lumen Cycle will process rigid lumened devices in around 60 minutes
  • The Flexible Cycle will process flexible scopes in around 38 minutes
  • The Non Lumen Cycle will process general stainless steel and non lumened devices in around 28 minutes
  • For the fastest turn-around, the Fast Cycle will process instruments and instruments in pouches or pouched trays in around 19 minutes. Please confirm that the pouches and trays are validated for the Fast Cycle.

What STERIS accessories are designed to work with the V-PRO s2 Low Temperature Sterilizer?

A wide range of products are available to be used with the V-PRO s2 Low Temperature Sterilizer:

What is the difference between STERIS’s V-PRO Low Temperature Sterilization Systems?

Explore the differences between V-PRO Sterilizers and other common VH2O2 Sterilizers based on important factors like chamber size, cycle time, utilities, electronic record-keeping capabilities, and more using our interactive tool.

Go to Top of Page
 

Planning and Design

View, download and print technical information for V-PRO s2 including CAD Blocks, Revit Family Objects, equipment drawings, technical data sheets, and more on the STERIS Architect Portal.

ACCESS DESIGN RESOURCES

Go to Top of Page
 

Literature

OPERATORS MANUAL
Document # Document Title
V-PRO S2
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM
TECH DATA SHEET
Document # Document Title
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM
TECHNICAL MONOGRAPH
Document # Document Title
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM
MONOGRAPHIE DES DONNÉES TECHNIQUES - SYSTÈME DE STÉRILISATION À BASSE TEMPÉRATURE V-PRO S2
LABORATORY REPORTS
Document # Document Title
VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS
VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS
WALL CHARTS
Document # Document Title
PACK MONITORING WALL CHART
V-PRO S2 CYCLE WEIGHT GUIDE
V-PRO S2 CYCLE WEIGHT GUIDE
V-PRO S2 CYCLE WEIGHT GUIDE
BROCHURE
Document # Document Title
V-PRO CONSUMABLES BROCHURE
V-PRO S2 BROCHURE (ENGLISH)
V-PRO S2 BROCHURE (CANADA)
V-PRO S2 BROCHURE (FRENCH)
SELL SHEET
Document # Document Title
INFOGRAPHIC- V-PRO BEATS STERRAD WITH A 1-2 PUNCH
SAMPLE PROCEDURES
Document # Document Title
QUALIFICATION TESTING OF V-PRO STERILIZERS FOLLOWING INSTALLATION OR MAJOR REPAIR
Go to Top of Page
 

Related Products

Go to Top of Page