The V-PRO s2 Low Temperature Sterilizer delivers the right cycles to meet your Sterile Processing Departments' (SPD) demands while fitting in the tightest spaces of your facility at just 22 ½" wide. This compact, low temperature sterilizer also offers a 19-minute cycle for quick turnaround of devices. Delivering maximum productivity.
How the V-PRO s2 Low Temperature Sterilization System Works
The V-PRO s2 Low Temperature Sterilization System is a vaporized hydrogen peroxide (VH2O2) sterilizer that uses VAPROX™ HC Sterilant and provides terminal sterilization of properly prepared (cleaned, rinsed, and dried) medical devices. This compact sterilizer offers pre-programmed cycles that operate at low temperatures, processing medical devices without leaving toxic residues. Pre-programmed cycles include:
Cycle | Lumen† | Non Lumen | Flexible† | Fast† |
---|---|---|---|---|
†Refer the operator manual for lumen size limitations. *da Vinci is a registered trademark of Intuitive Surgical, Inc. |
||||
Cycle Time | 60 Minutes | 28 Minutes | 38 Minutes | 19 Minutes |
Load Weight | ≤ 11lb/5 kg | ≤25 lb/11.3 kg | 1 Scope | ≤11 lb/ 5kg: 1 Scope and Non Lumened and Lumened Devices |
≤4 lb/1.8 kg, Peel Pouch Only |
Device Examples |
|
|
|
|
Please refer to the Operator Manual for detailed lumen dimension information and how to identify devices for loads.
Why Choose the V-PRO s2 Low Temperature Sterilization System?
Supporting Your Sustainability Goals
Olympus®
Device Type | Model |
---|---|
Bronchoscopes | BF, such as BF1T60 |
Cystoscopes | CYF, such as CYF V2 |
Pleuroscope | LTF, such as LTF VH1 |
Karl Storz®
Device Type | Model |
---|---|
Ureteroscope | 11278AU1 |
Rhino Pharyngoscope | 11101RP2 |
C-Mac Intubation Fiberscope | 11302BD2 |
Fiberscope |
Stryker®
Device Type | Model |
HD Cameras |
1488-010-000 |
Medline®
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Cardinal Health™
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Halyard Health®
Device Type | Model |
---|---|
Sterilization Wraps | Various |
Visit the V-PRO Device Matrix to find out if your device can be reprocessed in a V-PRO Low Temperature Sterilization System. The Device Matrix contains information on devices from hundreds of manufacturers including:
Seamlessly connect and get immediate results from your V-PRO s2 Low Temperature Sterilizer and Celerity Incubator with ConnectAssure Technology. ConnectAssure Technology Data Export software helps promote compliance throughout the facility by interfacing compatible STERIS products with SPM Surgical Asset Tracking Software and many of the other leading instrument tracking systems.
What can the V-PRO s2 Low Temperature Sterilizer sterilize?
The V-PRO s2 Low Temperature Sterilizer can sterilize more than just instruments that are heat sensitive. Devices like batteries, rigid endoscopes, general stainless steel instruments, bronchoscopes, and others will benefit from short cycle times with a gentle, low temperature process.
How fast can the V-PRO s2 Low Temperature Sterilizer sterilize?
The V-PRO s2 Low Temperature Sterilizer has four cycles that range from fast to extremely fast, with all cycles starting with a moisture checking condition phase included in the total time:
What STERIS accessories are designed to work with the V-PRO s2 Low Temperature Sterilizer?
A wide range of products are available to be used with the V-PRO s2 Low Temperature Sterilizer:
What is the difference between STERIS’s V-PRO Low Temperature Sterilization Systems?
Explore the differences between V-PRO Sterilizers and other common VH2O2 Sterilizers based on important factors like chamber size, cycle time, utilities, electronic record-keeping capabilities, and more using our interactive tool.
OPERATORS MANUAL
|
|
---|---|
Document # | Document Title |
V-PRO S2 | |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM |
TECH DATA SHEET
|
|
---|---|
Document # | Document Title |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM |
TECHNICAL MONOGRAPH
|
|
---|---|
Document # | Document Title |
V-PRO S2 LOW TEMPERATURE STERILIZATION SYSTEM | |
MONOGRAPHIE DES DONNÉES TECHNIQUES - SYSTÈME DE STÉRILISATION À BASSE TEMPÉRATURE V-PRO S2 |
LABORATORY REPORTS
|
|
---|---|
Document # | Document Title |
VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS | |
VALIDATION OF DOUBLE POUCH MICROBIAL EFFICACY IN V-PRO AND STERRAD STERILIZERS |
WALL CHARTS
|
|
---|---|
Document # | Document Title |
PACK MONITORING WALL CHART | |
V-PRO S2 CYCLE WEIGHT GUIDE | |
V-PRO S2 CYCLE WEIGHT GUIDE | |
V-PRO S2 CYCLE WEIGHT GUIDE |
BROCHURE
|
|
---|---|
Document # | Document Title |
V-PRO CONSUMABLES BROCHURE | |
V-PRO S2 BROCHURE (ENGLISH) | |
V-PRO S2 BROCHURE (CANADA) | |
V-PRO S2 BROCHURE (FRENCH) |